12 MW Used Steam Turbine

SIEMENS EG 400-2

The back pressure steam turbine is running now.

Gearbox unit was changed with new one in 2006

Oil heat exchanger was changed in 2010

It was maintained in 2011

Steam Turbine

Inlet Pressure Rated: 56 Bar G
Inlet Steam Flow Rate: 80 t/h
Extraction Pressure Rated: 13 Bar G
Extraction Temperature Rated: 300 C
Exhaust Pressure Rated: 5 Bar G
Rated Speed: 8.000 Rpm
Output Power: 12.920(~95.00 kW) PS

Generator

Rated Power: 12.500 kVA
Rated Voltage: 6.300 Volt
Frequency: 50 Hz
Speed: 1500 Rpm
Power Factor: 0,8
Cooling Type: Water/Air cooled
Excitation: With Carbon Brush